3) Once you hear the buzzer sound or see the warning LED in RED, please check,
a) If the loading is under the minimum or over the maximum load of each
channel.
b) If the power source is well connected and supplied.
Shall the above condition is happened, please disconnect the power source and
wait for 2-3 minutes to release the protection status; then test it again.
c) If buzzer keeps alarming or LED indicates the power module failure, please
locate which power module is defective. Perform hot-swap procedures (ref. to
Sec. 1.8 Hot-Swap Procedures). Return the defective power module back to
your vendor for RMA procedure.
d) If you can not fix the problem, please contact your vendor for supporting.