INPUT CHARACTERISTICS: R2W-6500P
VOLTAGE: 105 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 Hz
INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC
INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT REGULATION OUTPUT
MIN.[A] MAX.[A] PEAK(A) LOAD LINE
5V 2.0 30
±
5%
±
1%
50mV
12V 2 32
±
5%
±
1%
120mV
-5V 0.05 0.7 +5/-10%
±
1%
120mV
-12V 0.05 0.7 +5/-10%
±
1%
120mV
3.3V 1.0 24
±
5%
±
1%
50mV
+5VSB 0.1 2.0 + 6/-5%
±
1%
50mV
OUTPUT
VOLTAGE
RIPPLE & NOISE
MAX. [P-P]
REMARKS: TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 43 A; total
output power not exceed 500w
. TEMPERATURE RANGE : OPERATING 0
0
C --- 40
0
C, STORAGE –20
0
C --- 70
0
C
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
EFFICIENCY: 68% TYPICAL, AT FULL LOAD 115V
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
OVER LOAD PROTECTION: 110 ~ 160% MAX.
OVER VOLTAGE PROTECTION:
+5V 5.7V ~ 6.5V, 3.3V 3.9 ~ 4.3V, 12V 13.3 ~ 14.3V
. OVER CURRENT PROTECTION
EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
REMOTE ON / OFF CONTROL
FAULTY ALARM METHODS : LED, BUZZER, TTL SIGNAL
HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
REMOTE SENSING DESIGN
ISOLATION: BUILT-IN IN THE POWER MODULE
MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )
DIMENSION: 84(H) X 101(W) X 300 (D) mm
COOLING : TWO 38x38x28 mm DC FANS (MODULE)
AC INLET IN EACH MODULE